Alsanza aspheric IOLs designed to control corneal positive spherical aberrations with its mild spherical aberration correction. 24H aspherical correction leaves weak spherical with longitudinal focus as young adaptive eye behaves.
Provides continuous contrast sensitivity in low light conditions as well as photopic conditions.

Why Aspheric Correction is so crucial?

When parallel rays pass through the spherical surface, the central rays focus on more posteriorly and peripheral rays focus more anterior progressively. In the IOLs without aspherical correction, peripheral rays are bent too much .Specially at dim night conditions, Spherical aberrations increase as a result of expanded puppil size due to  defocusing of improper refracted light.

Total spherical aberrations will result;

  • Astigmatism-like aberration
  • Light scatterings in mesopic conditions

Arms2FIT Haptic design adds a new perspective to traditional C-loop design.
Unique Suspensive Additions;

  • Narrow Junction Angle improves suspensive movements of Arms to maintain IOL and optical field stability.
  • Stress Dimmer Curves of inner arms softens transmitted stresses to support function of Narrow junction angle and Suspensive FITarms
  • Both Flexy and Strong FIT Arms Minimize tiltations mainly resulting from contractions, tensile or bending stresses sourced by crystalline bag. Support Harmony between Crystalline Bag & IOL to preseve desired refractive stability.

High Dioptric Accuracy

Alsanza Optic Intellegence standardize more sensitive dioptric deviation control than international standardizes. Manufacturing process ensures to perform High Dioptric Accuracy in total range of IOLs with 0.25D a very low dioptric deviation value comparatively

MTF Value: 0,60 at 100 lpm
With 0,60 at 100 lpm, ALSANZA IOLs presents one of highest MTF value in competiton Optic quality of ALSANZA IOLs present well above International standards. Permitted MTF value is established as only 0,43 at 100 lpm for global IOL manufacturers ALSANZA executes strict control mechanism to maintain high standards by individually checking MTF values of each product in line.

Prevention of posterior capsular opacification is an important component of global patient satisfaction and desired continuous Optic Quality

All ALSANZA IOLs have most prominent edges with Diamond Cut Edge design that frames all optical field. More sharpened design of Diamond Cut Edge most effectively blocks LEC migration than conventional square edge & Non-edged designes.

  • Diamond Cut Edge frames all optical field in continuous form.
  • All surface properties and Diamond Cut edge design of Alsanza IOLs devoleped for Anti-Migration effect onLECs and reduce PCO occurence.

A glistening Free Hydrophobic Acrylic IOL

Packed in dry conditions Safe platfrom with performing Diamond Cut Edge Design Foldability- Resistance to distortionPremium aspheric optic concept

MaterialHydrophobic acrylic
Optic Size6.00mm
Optic DesignBiconvex Aspheric
Haptic Size13.00mm
Haptic DesignModified C
Haptic Angle
Recommended Op. A Constant118.0
Diopter Power Range0.00D – 32.00D (0.50 D increments)
Tg (Glass transition temperature)-2.0 °C
PhotoprotectionUV Filtration
Refractive Index Dry20°C /35°C 1.531 / 1.533 ± 0.002
Recommended Injector&AlsaJET (1.8 mm and 2.2 mm)
  1. Suspensive Arm design with Stress Dimmer Curves
  2. Symmetrical anterior and posterior asphertic optic
  3. Diamond Cut Edge Design
  4. Arms2FIT Haptic
MaterialHydrophobic acrylic
Optic Size6.00mm
Optic DesignBiconvex Aspheric
Haptic Size11.00mm
Haptic DesignPlate Haptic
Haptic Angle
Recommended Op. A Constant118.0
Diopter Power Range0.00D – 32.00D (0.50 D increments)
Tg (Glass transition temperature)-2.0 °C
PhotoprotectionUV Filtration
Refractive Index Dry20°C /35°C 1.531 / 1.533 ± 0.002
Recommended InjectorAlsaJET (1.8 mm and 2.2 mm)
  1. Positoning and ODV removal holes
  2. Symmetrical anterior and posterior asphertic optic
  3. Diamond Cut Edge
  4. Suspensive Corner Fins
  5. Fins4FIT Haptic

*4 Self-adaptive Corner fins for customized adaptation to various capsular bag dimensions.

Alsanza

Alsanza Medizintechnik und Pharma GmbH
Hermann-Burkhardt-Str.3 D-72793
Pfullingen Germany
+49 (7121) 69 06 520  |  +49 (7121) 69 06 599
info@alsanza.com